Hampton II Active Replacement Mattress
Overview
The Hampton II Active Replacement Mattress is Harvest Healthcare’s durable and versatile alternating pressure mattress system, designed for the prevention and management of pressure ulcers in high-dependency care environments. Suitable for patients at very high risk of developing pressure damage, the mattress also supports the treatment of up to Stage 4 pressure ulcers.
Combining reliable pressure redistribution, patient comfort, and practical safety features, the Hampton II is designed to meet the demands of hospitals, care homes, nursing environments, and community care settings. Its durable construction and adaptable sizing options make it a dependable all-round solution for long-term pressure care.
Advanced Alternating Pressure Therapy
The Hampton II features a 20-cell alternating pressure system designed to continuously redistribute pressure across the patient’s body. The cells inflate and deflate in a controlled cycle, helping to reduce prolonged pressure on vulnerable areas and improve circulation.
This alternating therapy helps to:
Reduce the risk of pressure ulcer development
Support treatment of existing pressure damage
Improve patient comfort during long-term bed rest
Promote healthier skin integrity and circulation
The mattress includes a dedicated pillow section that remains stable during operation, providing additional comfort and support for the patient’s head and upper body.
Quiet and Durable Cell Construction
The mattress cells are manufactured from durable nylon with a TPU lining. This combination provides excellent strength and reliability while helping to minimise operational noise during inflation and deflation cycles.
The quieter operation contributes to a more comfortable and restful environment for patients, particularly during overnight use in care settings.
The robust construction also supports long-term durability, making the Hampton II suitable for demanding healthcare environments where reliability is essential.
Transport and Emergency Features
The Hampton II is designed with practical patient handling and transport features to support safer care routines.
The connector system includes a transport cap that maintains air pressure within the mattress during patient transport or temporary movement. When the transport cap is used correctly, the mattress can remain inflated for approximately 24 hours without power.
For emergency situations, the system includes a CPR quick-release function. By opening the CPR valve and disconnecting the pump, the mattress rapidly deflates to allow immediate clinical access when required.
Protective Mattress Cover
The mattress is supplied with a high-quality 4-way stretch welded PU cover designed to support both patient comfort and infection control.
The cover offers:
Vapour permeable material to help maintain skin health
Water-resistant protection against fluid ingress
Welded seams for improved durability and hygiene
Crib 5 fire rating for healthcare safety compliance
4-way stretch fabric to support effective pressure redistribution
These features make the mattress suitable for demanding clinical and residential care environments.
Versatile Sizing Options
The Hampton II mattress is available in multiple sizes to suit different patient requirements and bed configurations.
Available options include:
This flexibility allows healthcare providers to select the most appropriate configuration for standard and specialist care environments.
Pump Compatibility and Patient Support
The Hampton II is compatible with all Harvest Healthcare pumps, allowing the mattress system to accommodate a wide range of patient requirements and weight capacities depending on the selected pump.
This flexibility makes it suitable for a variety of care settings, from standard nursing care through to higher dependency pressure care management.
Designed for Long-Term Pressure Care
The Hampton II has been developed as a reliable all-round pressure care solution that combines durability, comfort, and advanced alternating therapy. Its practical features, transport capability, and robust construction make it ideal for long-term patient care where consistent pressure relief and ease of maintenance are essential.
Key Features
Alternating pressure replacement mattress system
Suitable for prevention and treatment of up to Stage 4 pressure ulcers
20 durable nylon cells with TPU lining
Quiet inflation and deflation operation
Stable pillow section for added patient comfort
Transport cap maintains inflation for up to 24 hours
CPR quick-release deflation system
4-way stretch welded PU cover
Vapour permeable and water-resistant construction
Crib 5 fire-rated cover
Available in 900mm and 1050mm widths
Optional 2200mm length available
Compatible with all Harvest Healthcare pumps
Suitable for hospitals, care homes, and community care settings
The Hampton II Active Replacement Mattress delivers a dependable and adaptable pressure care solution for high-risk patients. Combining advanced alternating pressure therapy with durable construction and practical safety features, it provides reliable support, comfort, and pressure ulcer management across a wide range of healthcare environments.