Invacare Softform Premier Active 2 Pressure MattressThe Invacare Softform Premier Active 2 Pressure Mattress comes with the Active 2 RX pump. The Hybrid replacement pressure mattress provides a dual support surface, which redistributes pressure for the user. The clinically proven design of the Softform Premier foam mattress, combined with the optional alternating air cell layer, provides effective treatment and prevention of pressure ulcers. With the simple addition of the RX Pump the Pressure Mattress turns into a dynamic support surface, offering additional levels of pressure redistribution, providing a comfier and more supportive mattress for the user.This Pressure Mattress is for those who are in the Very High risk category of developing pressure ulcers/sores.The Mattress can be used as a standard static foam mattress for those who do not require alternating air for redistribution, making it the ideal mattress in care enironments as the mattress can be downgraded/upgraded depending on the individuals needs.The Invacare Softform Premier Active 2 Pressure Mattress comes as standard, 830 mm x 900 mm. This however can be altered for a wider or longer mattress platform. Please call our amazing team on 01772 814555 and we will be more than happy to help.Specifications:Mattress SpecificationsWidth: 830 mmlength: 1810 mmHeight: 152 mmProduct Weight: 14 kgSafe Working Load: 247.6 kgPump SpecificationsDepth: 105 mmWidth: 275 mmHeight: 155 mmProduct Weight: 1.75 kgFeatures:- Lightweight Mattress and Pump- Washable at 80 degrees- 2-in-1 Mattress technology- Upgraded/Downgraded to meed individuals pressure care needs- Easy to use digital display - Pump unit is extremely quiet when powered- Very High Risk Category..
Invacare Softform Premier ActiveCARE MattressThe clinically proven Softform Premier ActiveCARE mattress offers a 'Very High Risk' high specification static surface. Should a patient require stepping up to a dynamic surface, a discreet pump can be fitted to the air insert, transforming the mattress into an alternating surface, delivering additional levels of pressure relief. There is no requirement to transfer the client, thereby minimising any discomfort and reducing manual handling. The mattress is suitable for service users in Community and Residential Care environments.Static Dynamic MattressThe air insert contained within the mattress allows stepping up and down between static and dynamic alternating systems with minimum patient disruption.Digital PumpPowered by an innovative digital pump, the air cells within the mattress alternate on a ten minute cycle, delivering a very low impact at the point of change. This significantly enhances patient comfort whilst providing effective pressure relief.Specifications:ActiveCARE MattressWidth: 880 mmLength: 2000 mmHeight: 152 mmWeight: 14 kgMaximum User Weight: 247.6 kg (39 stone)Maximum cleaning temperature: 80 degreesWarranty: 2 yearsColour: Baltic BlueActive 2 RX PumpDepth: 105 mmWidth: 275 mmHeight: 155 mmWeight: 1.75 kgWarranty: 2 yearsFeatures:- Offers stable support with improved comfort- Cost saving construction- Digital pump- Easy read LED display- Very High Risk Mattress- Larger brackets for pump to fit onto bed ends..
Liberty II Advance Turn Mattress The liberty II advance turn mattress can help reduce the need for an assisted roll and in doing so reduce the stress on the patient and reduce the cost of care packages. With the option of full, right or left turn up to 40 degrees to assist manual or automatic turn, with varying times between 10-90 minutes. It is constructed of deep 8" cells, in a cell-on-cell design and provides dual therapy modes. The static base and head cells provide support and stability, the leg zone provides lower residual interface pressure in this highly sensitive area and true low air loss therapy reduces the heat and moisture. Specifications Maximum user weight: 450 kg Mattress dimensions: 2000 mm x 1220 mm x 300 mm Power unit dimensions: 400 mm x 150 mm x 280 mm Mattress weight: 12.5 kg Power unit weight: 6.2 kg Features Cell-on-cell construction Static transfer walls Premium quality TPU coated nylon cells Lower leg zone CPR release valve Strong cell retention knitted bands ..
Liberty II Bariatric Mattress Replacement The liberty II bariatric dynamic low air loss mattress replacement provides continuous low pressure and is designed for use with patients considered to be up to a very high risk of developing pressure ulcers. The system is particularly suitable for use with terminally ill and frail patients together with the treatment of burns and lymph-oedema. Specifications Maximum weight capacity of 450 kg Mattress dimensions: 2000mm x 1220mm x 200mm Power unit dimensions: 390mm x 280mm x 185mm Product weight: 12.5 kgPower unit weight: 6.2 kg FeaturesCell-on-cell constructionLower leg zonePremium quality TPU coated nylon cells CPR release valve Strong Cell Retention knitted bands Soft waterproof vapour permeable quilted cover 360 degree zipper Welded seams and enclosed zipIntegral covered air pipe Cable management system ..
Liberty II Mattress Replacement The liberty II dynamic low air loss mattress replacement provides continuous low pressure and is designed for use with patients considered to be up to a very high risk of developing pressure ulcers. The system is particularly suitable for use with terminally ill and frail patients together with the treatment of burns and lymph-oedema. Specifications Maximum weight capacity of 320 kg Mattress dimensions: 2000mm x 890mm x 200mm Power unit dimensions: 390mm x 280mm x 185mm Product weight: 10.5 kgPower unit weight: 6.2 kg FeaturesCell-on-cell constructionLower leg zoneCPR release valve Strong Cell Retention knitted bands Soft waterproof vapour permeable quilted cover 360 degree zipper Welded seams and enclosed zipIntegral covered air pipe Cable management system ..
Hospitalized Patients and Pressure Injuries:44% of hospitalized patients develop pressure injuries (PI), which increases their mortality risk by 6 times.PIs that progress to partial skin loss (pink wound, S/C II) typically require more than 8 weeks to heal, resulting in additional costs.Effective Repositioning:Regularly turning patients helps prevent compression of bony areas and improves skin blood circulation.A 30° turn is more effective than a 90° turn (usual care) for enhancing skin blood circulation.Challenges Faced by Nursing Staff:62% of nursing staff experience lower back injuries from handling patients.These injuries contribute to burnout, exacerbate healthcare shortages, and negatively impact care quality and patient outcomes.Optima Turn Solution:Automates 30° lateral turns with customizable turning cycle options.Reduces nursing injuries and bottlenecks during repositioning.Side bolsters protect patients from pressing against bed rails, ensuring safety and comfort.Optima Turn streamlines caregiver workflows, enhances safety, and promotes patient well-being during repositioning routines.
MATTRESSDimensions 200 x 85/90 x 13cm, side bolsters 25cmCell Height13cm cells with two turning cells underneath from 4th to 12th air cellsWeight11.4kgCover Material4 way stretch PU / Polyester Cover with welded seams Cell MaterialTPUCPR Knob1 PieceMaximum Patient Weight180kgFlame Retardant Standards EN 597-1 & EN 597-2PUMPDimensions34.1 x 16.5 x 26.0cmWeight4.5kgCase MaterialFlame Retardant ABSSupply Voltage220-240V/ 50Hz; 110-120V / 60HzOperating Cycle Time10,15,20,25 minDwell Time10,20,30,60 min..
Single Community Mattress ProtectorThis mattress protector is fluid proof, hygienic and economical. It is easily wiped clean and the protector is made from polypropylene. Flame Retardant to British Standard BS 7175. You can also get this mattress protector in a double size. ..
Single MRSA Resistant Mattress ProtectorThis mattress protector is quiet, soft and breathable due to the combination of four way stretch fabric and Smart Sheet design it ensures the protectors will fit a wide range of healthcare mattresses. It is Flame Retardant to the European Standard EN ISO 12952. They can be simply wiped clean or washed up to 95° and i can be tumbled dried on a medium heat. It is also available in a double bed size...
Tamora II Digital Mattress ReplacementThe tamora II digital provides highly effective care and protection for patients considered to be up to a high risk of pressure ulcer development and is suitable for use in a wide range of care settings from general war and acute care to private or nursing home care. Specifications Maximum user weight of 200 kg Mattress dimensions of 2000 mm x 850 mm x 130 mm Power unit dimensions of 320 mm x 130 mm x 230 mm Mattress weight of 4.9 kg Power unit weight of 3.5 kg Features 2-Cell cycle Comfort control Digital control panelTransport mode Static modeAuto-lockout function Rapid CPR deflation Audible and visual alarms Automatic control panel lockout Securing straps..
Tamora II Mattress ReplacementThe tamora II is a lightweight, portable mattress overlay system that is suitable for use in a wide range of care settings from general ward and acute care to private or nursing home care. Ideal for patients considered to be up to a high risk of pressure damage the Tamora II is and optimal pressure care solution. Specifications Maximum user weight of 200 kg Mattress dimensions of 2000 mm x 850 mm x 130 mm Power unit dimensions of 320 mm x 130 mm x 230 mm Mattress weight of 4.9 kg Power unit weight of 3.5 kg Features 2-Cell cycle Comfort control Transport mode Timed static modeAuto-lockout function Rapid CPR deflation Audible and visual alarms Automatic control panel lockout ..
Tamora III Advance Mattress Replacement The Tamora III advance dynamic 24-cell mattress replacement system provides highly effective care and protection for patients considered to be up to a very high risk of pressure ulcer development and is a cost effective solution for any healthcare environment. A flexible range of features allow the tamora III advance to provide individualised patient care. The system offers both dynamic, static and constant low pressure therapy modes allowing nursing staff to adjust the therapy and comfort offered to patients. Specifications Maximum weight capacity of 255 kg Mattress dimensions: 2000mm x 900mm x 200mm Power unit dimensions: 320mm x 130mm x 230mm Cycle time of 10/15/20/25/30 mins (3 cell cycle) Features 3-Cell cycleComfort controlDigital control panelTransport mode Auto-lockout function Static Mode Inflation time Rapid CPR deflation Audible and visual alarms Adjustable hanging brackets Stretch waterproof, vapour permeable PU cover Welded seams and enclosed zip Easily accessible 360 degrees zip Integral and covered air pipeSecuring straps ..
Tamora Plus II Digital Mattress ReplacementThe tamora plus II digital dynamic mattress replacement system provides highly effective care and protection for patients considered to be up to a very high risk of pressure ulcer development and is a cost-effective solution for any healthcare environment. Specifications Maximum user weight of 200 kg Mattress dimensions of 2000 mm x 850 mm x 180 mm Power unit dimensions of 320 mm x 130 mm x 230 mm Mattress weight of 8.9 kg Power unit weight of 3.5 kg Features 2-Cell cycle Comfort control Digital control panel Transport modeAuto-lockout function Static modeRapid CPR deflation Audible and visual alarms Adjustable hanging brackets Stretch waterproof, vapour permeable PU cover ..